Making sure you’re not a bot!
For solar-only case (Fig. 20 a) the use of the NEC/DNEC pair shows the highest capacity factor of the electrolyser with the lowest solar-electrolyser ratio of 7.69. However, the size of the dehydrogenation reactor is considerably larger for NEC compared to other LOHCs, due to its very high STY of the dehydrogenation. For the solar-only case (Fig. 19a) NEC/DNEC pair requires the smallest size of all equipment, while DBT requires the largest. The HPC and capacity factor are highly dependent on the performance of energy sources. Blue bars indicate the HPC excluding the cost of the hydrogen dispensing unit; orange bars indicate the HPC including the cost of the hydrogen dispensing unit.
22 to 0, and the dehydrogenation reactor is utilised to meet the hydrogen demand. The fluctuation in grid electricity prices and energy consumption of heat pump. As the grid electricity prices decrease, the energy usage of the heat pump increases. There is an inverse relationship between the heat pump energy usage and gird electricity prices. Figure 16 shows the relationship between energy usage of heat pumps and grid electricity prices for the optimal scheduling of the HRS.
This study focuses on the HRS with onsite hydrogen production, hydrogen storage, heat management, and dispensing units, as shown in Fig. Although LOHCs have been considered for storage and transportation of hydrogen in various applications15,16,17,18,19, their applications in HRS have not been widely investigated. In 2018, Chiyoda Corporation in Japan built a pilot plant using SPERA technology for large-scale hydrogenation and dehydrogenation. One key advantage of this process is that the LOHC can be stored and distributed as a liquid at ambient temperature and pressure at both loaded and unloaded conditions.
The hydrogen outlet pressure from the PEM electrolyser is 30 bar, while the dehydrogenation reactor has a discharge pressure of 1 bar. These heat pumps have been developed for industrial applications, particularly for concentrated solar thermal power (CSTP) plants. In this study, dibenzyltoluene (DBT) is chosen as a hydrogen-lean carrier, and perhydro-dibenzyltoluene (PDBT) as a hydrogen-rich carrier for the base case analysis. When hydrogen reacts with a hydrogen-lean carrier in the hydrogenation reactor at a temperature of 150 ˚C and a pressure of 30 bar, a hydrogen-rich carrier is formed as a product and stored in a hydrogenation storage tank. Two reversible reactions are involved, which are hydrogenation and dehydrogenation.
However, the design capacity of the dehydrogenation reactor for NEC/DNEC with a solar PV price of A$2000 is nearly double that of other LOHCs. The design capacity of each piece of equipment is similar for the use of the same LOHC as shown in Fig. The design capacity of the dehydrogenation reactor is more sensitive to the changes in renewable energy prices than other LOHCs when using NEC/DNEC as LOHCs. The cost structure for equipment and electricity exported to the grid of different LOHC-based HRS when the capital costs of a solar PV system are (a) A$2000 (b) A$1500 (c) A$1000 respectively.
The variations in the capital and operating costs of all equipment as illustrated in Fig. The cost of dispensation electricity and dispensing unit remain constant in both scenarios and are not affected by the selection of LOHCs. The cost structure for equipment and electricity exported to grid of different LOHC-based HRS with (a) a solar PV-driven electrolyser and (b) a grid-connected electrolyser, in a unit of A$. The use of the DBT/PDBT pair results in the highest capacity factor of hydrogenation, while using MCH/TOL and DEC/NAP shows the highest capacity factor of dehydrogenation. For grid-only case (Fig. 20b), the electrolyser has a relatively high capacity factor when using either MCH/TOL or NEC/DNEC.
In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript. The task is calculated in a few seconds and you are granted access to the website.
The HPC for the HRS with a hydrogen production capacity of 500 kgH2/day is calculated by It is calculated based on the cost input variables and assumptions summarised in Sect. The procurement cost for equipment is an essential factor that can significantly affect the overall cost estimations. The optimisation was performed in hourly intervals to account for the reaction time of the hydrogenation and dehydrogenation processes. Julia is an open-source programming language that was used in this study for the linear programming (LP)-based optimisation problem for the HRS. The proposed process model considers an HRS with the entire hydrogen supply chain, including hydrogen demand forecast, hydrogen production, hydrogen storage, heat management, and dispensing units as illustrated in Fig.
However, the heat pump consumes only a small portion of the electricity. The amount of waste heat and energy loss generated by the electrolyser accounts for approximately 30% of the total electrolyser energy this reference page content. The PEM electrolyser is the main consumer of electricity, followed by the heat pump during the energy consumption stage. 26 shows the flow of solar energy and its transformation across various physical equipment of the HRS. In this study, the Sankey diagrams are used to visualise the energy flows, analyse the use of the electrical energy sources across the HRS, and identify the potential opportunities for energy efficiency improvement. Figure 25 illustrates the energy consumption for different LOHC-based HRS for different scenarios.